Metrology
Metrology
Millimess 2001 Inductive digital comparator
EN
  • High contrast LCD
  • Analog display with 4 mm pointer ensures better visual recognition, ideal when checking concentricity or flatness as well as searching for the reversal point when measuring bores
  • Operating and display unit (bezel) can be rotated through 280°
  • Mounting shank and measuring spindle are both made of hardened stainless steel
  • Measuring spindle is mounted in a high precision ball guide for minimal hystersis
  • Linearized inductive absolute measuring system
  • Measuring force spring is interchangeable
  • Lower stop is adjustable
  • Technical data
  • Functions

Order no.Product typeMeasuring range mm Measuring range inchMeasuring range 1 _beginning_ mmMeasuring range 1 _end mmMeasuring range 1 _beginning_inchMeasuring range 1 _end inchResolutionResolutionStandardMinimum measuring forceMaximum measuring forceHeight of digitsRange of analog display mmRange of analog display inchesIP protection category
4346100
2001
± 0.9
± .035"
-0.4 mm
0.4 mm
-0.015 inch
0.015 inch
0.001 mm / 0.001 mm / 0 mm
0 inch / 0 inch / 0 inch
Factory standard
0.7 N
0.9 N
6.5 mm
± 0,030 / ± 0,015 / ± 0,006
± .0015" / ± .0006" / ± .0003''
IP 54
4346910
2001
± 0.9
± .035"
-0.4 mm
0.4 mm
-0.015 inch
0.015 inch
0.001 mm / 0.001 mm / 0 mm
0 inch / 0 inch / 0 inch
Factory standard
0.7 N
0.9 N
6.5 mm
± 0,030 / ± 0,015 / ± 0,006
± .0015" / ± .0006" / ± .0003''
IP 54
4346911
2001
± 0.9
± .035"
-0.4 mm
0.4 mm
-0.015 inch
0.015 inch
0.001 mm / 0.001 mm / 0 mm
0 inch / 0 inch / 0 inch
Factory standard
0.7 N
0.9 N
6.5 mm
± 0,030 / ± 0,015 / ± 0,006
± .0015" / ± .0006" / ± .0003''
IP 54

  • ON/OFF
  • RESET (set display to zero)
  • 0 (set the analog display to zero)
  • PRESET (for entering a numerical value)
  • mm/inch
  • Reversal of counting direction
  • RANGE (switch the measuring range and resolution)
  • ABS (reference to the electrical zero point)
  • MAX/MIN memory for searching the reversal point
  • TIR (MAX-MIN) for testing flatness and concentricity
  • TOL (enter tolerance limit values)
  • Factor (adjustable)
  • Remote-controlled via interface (optoRS232/USB)